Trace oxygen analyzer can be widely applied in the online oxygen content analysis industries like the measurement of protection gas from high-temperature sintering furnace like magnetic material and brazing furnace, protection gas furnace for electronic-semiconductor and glasswork technique, etc.
Trace oxygen analyzer adopt an unique protection air circuit which can protect the sensor efficiently and prevent the sensor from being exposed in the air for too long to affect its serving life. The imported fuel-cell oxygen sensor is with long serving life, a rapid response speed, high measurement accuracy and long calibration cycle for features, etc.
1. Only one random point needs to be calibrated among the whole measurement range, and the measured accuracy among the whole measurement range can be met without multi-points calibration;
2. Function of built-in temperature compensation could eliminate the influence from the changes of environment • temperature on the measured accuracy;
3. Function of storing data automatically makes looking through historical data at any time possible;
4. Function of shifting Chinese-English menu makes the operation visual and easy;
5. Built-in imported extraction pump (optional).
Test principle | micro-fuel cell |
Display mode | 128*64 matrix dot LCD |
Test Range | 0 ~ 10/100/1000ppm,1.00%,25.00% O2 |
Resolution | 0.1ppm |
Accuracy | 0~1000ppm /1.00%/10.00% /25.00% ≤±1% FS 0~100ppm ≤±2% FS 0~10ppm ≤±5%FS |
Repeatability | ≤±1% |
Response time | T90≤60S |
Analog output | 4~20mA.DC(non-isolated output, loaded resistance lower than 500 Ohm) 0~10V.DC(non-isolated output, loaded resistance higher than 10k Ohm) 1 way programmable alarm output (Dry contact type, maximum load 220VAC/2A) |
Communication Port | RS232 (default) or RS485 |
Power supply | AC170 ~ 264V 50/60Hz |
Temperature of the sample gas | 0 ~ 50℃ |
Sampling mode | Sample gas pass-in or extraction |
Sample gas flow | 600 ~ 800ml/min |
Working pressure(without pump) | 0.05MPa≤entrance displayed pressure≤0.35MPa, steady pressure environment |
Working pressure(with pump) | micro-positive pressure, micro-negative pressure or ordinary pressure |
Background gas | He、H2、CO2、N2 and inactive gas |
Appearance Size | 177mm×251mm×343mm (H×W×D) |
Install Hole Cut | 179mm×213mm (H×W) |
Serving life | >24 months(under normal use) |
Gas circuit port | NPT 1/8 internal thread |
Install mode | frame mount |
Disclaimer: The product introduction content (including product images, product descriptions, technical parameters, etc.) of this site is for reference only. As the update may not be timely, there will be some differences between the content and the actual situation. Please contact our sales staff to confirm. The information provided on this site does not constitute any offer or promise, and the company will improve and modify any information on the website from time to time without prior notice.